Aquastar 125X User Manual

Browse online or download User Manual for Water boiler Aquastar 125X. AquaStar 125X User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 13
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION AND OPERATING INSTRUCTIONS
FOR AQ-1 POWER VENT KIT
DESIGNED FOR
BOSCH 425 HN WATER HEATERS
AQUASTAR 125B WATER HEATERS
INCLUDING AQUASTAR MODELS: 125HX • 125BS • 125X • 125BL
TABLE OF CONTENTS
contents with an AQ-1 power vent p.1
mounting gas pressure switch p.2
mounting linear spillage switch p.4
common setup p.6
locating vent hood (clearances) p.7
mounting power vent motor (clearances) p.7
troubleshooting and maintenance p.9
safety interlock test p.10
AQ-1 wiring diagram p.11
vent hood template p.12
8504077 rev. B 10.03
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - FOR AQ-1 POWER VENT KIT

INSTALLATION AND OPERATING INSTRUCTIONSFOR AQ-1 POWER VENT KITDESIGNED FORBOSCH 425 HN WATER HEATERSAQUASTAR 125B WATER HEATERSINCLUDING AQUASTAR MODE

Page 2 - AQ-1Power vent kit

3. Connect the RED wire from the jacketed cableonto the common terminal of the gas pressureswitch. (See Figure I)NOTE: If the distance between the p

Page 3

SAFETY INTERLOCK TEST1. Open the gas supply to the water heater.2. Remove the vent pipe from the vent connec-tor on the top of the water heater.3. Blo

Page 4

11HEATERECO SAFETY INTERLOCK DIAGRAMLINEAR LIMITSPILLAGE SENSINGSWITCH185ºMANUALRESETBLACK

Page 5

1. Attach this template to the interior of the wallthe Vent Hood will be penetrating.2. Insure that proposed vent termination clear-ances are met befo

Page 6 - FIGURE C

AQ-1Power vent kitParts included:Spillage Switch Kit1. 185º F linear spillage switch mounted on anangled bracket and equipped with 36 inchcables conne

Page 7 - COMMON SETUP

Power Vent KitCAUTION1. Failure to install, maintain and/or operate thePower Venter in accordance withmanufacturer's instruction may result incon

Page 8

INSTRUCTIONS (SEE DIAGRAMS ABOVE)1. Mount gas pressure switch by securing it tothe chosen location with a screw in each oneof the four mounting holes.

Page 9

e. Hand thread the pressure tap fitting intothe heater's burner manifold. Use a smallamount of an appropriate thread sealant on themale end of

Page 10 - AND TEST PROCEDURES

1. The ECO is mounted on the lower leftoutlet water pipe. (See figure C)a. Remove one lead connecting to ECOterminal, it does not matter which one i

Page 11

COMMON SETUPMount gas pressureswitch against wall6125B Model shownSee Figure D, page 5 for location of Linear Spillage SwitchVent Hood (see freeze pr

Page 12 - SENSING

CAUTIONFailure to follow these installationinstructions may violate applicablenational and/or local codesThe vent system must terminate so that pr

Page 13

INSTRUCTIONS(DO NOT BEGIN THESE PROCEDURESUNTIL VENT HOOD HAS BEENINSTALLED)1. Remove vibration mounts, nuts and washersfrom parts bag. Install on po

Related models: 125HX | 125BS |

Comments to this Manuals